Adaptive Reuse of Existing Buildings to Laboratories
Don Posson, PE, CIPE,
Kling
Chris Leary, AIA, The Stubbins Associates,
Inc.
The most sustainable laboratory project is one that reuses or renovates
an existing building shell to improve the performance of the building
as a whole. There are many examples of renovating existing laboratory
buildings to improve their overall energy performance and functional
efficiency. Although these renovations are challenging, they are
generally straightforward renovation projects as the building shell
and infrastructure were designed for a laboratory function.
A much greater challenge, however, is to convert an existing building
that was not originally utilized as a laboratory to a laboratory
function for either research & development, manufacturing, or
for teaching. These adaptive reuse projects are extremely challenging
and require a significant focus on upgrading the building envelope
to not only meet current energy codes but also to deal with the
more stringent space temperature, humidity, and pressurization requirements
of a laboratory. Also, because the floor-to-floor heights of the
buildings and the building volumes available were not originally
designed for the typically laboratory infrastructure provided, and
the design solutions for the building systems must be carefully
and creatively integrated between architecture and engineering.
The presentation will focus on theses design and construction challenges
and will provide several case studies where these challenges have
been successfully addressed.
Findings:
The lessons learned from the four case studies presented will focus
on the following aspects of adaptive reuse projects:
- Building Envelope Upgrades
- Building Character Transformation
- Options to work with less than ideal existing column bay spacing
and floor-to-floor heights
- Structural Vibration Concerns
- Utility Distribution Concepts
- Utility Service Upgrades
- Additional service requirements for lab buildings
- MEP Systems Appropriate to Adaptive Reuse Facilities
Labs21 Connection:
The approach suggested by this presentation is important because
it embraces one of the most fundamental sustainable principles of
recycling or reusing existing facilities in-lieu-of building new,
and in doing so working diligently to meet the energy performance
and functional performance strategies promoted by Labs21.
Biographies:
Don Posson, PE, CIPE, has over 18 years of experience specializing
in HVAC, plumbing and fire protection systems design for laboratory
facilities. Don is currently employed by Kling as an Engineering
Design Principal, working on the planning and design of R&D
facilities for the federal government, corporate biotechnology laboratories
and university teaching/research facilities. Don is a LEED
2.0 Accredited Professional and has been involved with the planning
and design of numerous sustainable design projects, including the
first LEED Platinum certified building. He has presented case
studies and sustainable design methodologies at conferences and
meetings hosted by the U.S. Green Building Council, the AIA Committee
on the Environment, the Construction Specifications Institute, Laboratories
for the 21st Century, and the Sustainable Washington Alliance. Don
is currently guest lecturer and studio critic for a comprehensive
architectural design studio at the University of Maryland, incorporating
advanced technology and sustainable design.
Chris Leary, AIA, has led design teams for many of the firm's
large-scale projects since joining The Stubbins Associates in 1992,
including laboratory and research facilities for the Novartis Institute
for Biomedical Research, Boston University Medical Center, and Vanderbilt
University Medical Center. His particular interest is in the area
of Building Performance and Sustainable Design. Chris is a LEED
2.0 Accredited professional, and is currently working on several
LEED registered projects. He is an experienced speaker on
the subject, and has participated in several conferences. In addition,
he is the Director of the Stubbins Associates High-Performance Green
Building Design Group.
Back to the Agenda
|